Power supply | 230 V, 50Hz |
Connecting cable | NYM-J (max. 5 x 2.5 mm2) |
Fuse | T4AH |
Dual mode | Yes, hybrid (wireless and wired) |
Operating temperature | 0 ... 50 °C |
Status signalling | LED indications |
Control function | Hysteresis (1K) |
Switching element | Triac and relay for pump and boiler |
Communication | 2 x RS485, 2-way-ISM wireless connection, Bluetooth 5 |
Radio transmission | 868 MHz, (band width: 865…868 MHz) |
Transmission power | 20 mW (+13 dBm) |
Wireless module | RFM69CW-868-S2 Hoperf |
Wireless antenna | 086AT43A0020E Jonson Tech |
Software | Class A according to PN-EN 60730-1 |
Installation | On-wall, DIN TS35 (DIN rail) |
WiFi module | 2FLOOR APP, 2FLOOR WebCLOUD, Cloud 30bx optional |
Connection extension | Connection of max. 4 successive EAZY 2FLOOR Base stations |
Heating zones | 8 |
Actuators (maximum) | 17 |
Output voltage for actuators | 230 V |
Operating direction of the actuator | NC / NO |
Connection cable of the actuator | 2 x 0.75 mm2 |
Connecting line - wired system | 2x2, 0.25 ... 1.00 mm2 (4 cores) |
Outputs of actuators | 3x3 + 5x2 |
Power per output | max. 2 W |
Protection class | IP 20 |
Relative humidity | 5 … 85 % without condensation |
Storage temperature | -10 ... +65 °C |
Valve protection function | every 14 days for 10 minutes |
Pump protection function | every 10 days for 5 minutes |
First-Open unlocking | 10 minutes |
Change-over heating/cooling | Yes, manually or via an external switching signal |
Modes | Antifreeze, day, night, time programme |
Dimensions / weight | 325 x 90 x 50 mm / 0.8 kg |